Product name: Arteriosclerosis detector KAS6800
Product parameters:
Product model: arteriosclerosis detector KAS6800
Scope of application: used for early screening of structural and functional lesions of human artery
Domestic/imported: domestic
Medical/household: medical
Sellable place: nationwide
The KAS6800 arteriosclerosis detector is a newly launched product by Nanjing Kejin. The arteriosclerosis detection device can screen for peripheral arterial obstruction and arterial stiffness by measuring parameters such as PWV (pulse wave conduction velocity), ABI (ankle brachial index), BAI (arm ankle index), etc. in the human body. The arteriosclerosis detector is easy to operate, with automatic analysis of detection results and providing screening opinions. It can achieve early detection, screening, and intervention of peripheral arterial diseases and cardiovascular and cerebrovascular diseases.
Collect electrocardiogram, heart sound, and limb pulse wave signals within the same cardiac cycle to calculate baPWV and evaluate the degree of vascular sclerosis. Synchronized compression of limbs, measurement of limb blood pressure to calculate ABI and evaluate the degree of arterial stenosis and obstruction in the lower limbs.
Features of the KAS6800 arteriosclerosis detector:
Vascular stiffness testing
PWV (Pulse Wave Conduction Velocity) is used to evaluate stiffness indicators of the aorta, major arteries, and middle arteries.
Heart rate variability function
Determine cardiovascular autonomic function through R-R interval mean, R-R interval standard deviation, R-R interval mean, HR mean, CVRR, R-R histogram, R-R trend chart, and electrocardiogram.
Exercise load test mode
Screening for lower limb artery risk in individuals with critical ABI or intermittent follow-up.
Degree of arterial obstruction in the upper and lower limbs
ABI (ankle brachial index) is used to evaluate the degree of arterial obstruction in the lower limbs;
BAI (Arm Ankle Index) is used to evaluate the degree of proximal arterial obstruction in the upper limb.
Applicable departments of the arteriosclerosis detector:
Endocrinology, Physical Examination Center, Vascular Surgery, Hypertension, Neurology, Cardiovascular Medicine, Functional Medicine.
Product details of KAS6800 arteriosclerosis detector:
Arteriosclerosis detector auxiliary support arm
The auxiliary arm of the arteriosclerosis detector is a patented design by Nanjing Kejin Industrial Co., Ltd. (patent number: ZL 2022 3 0045108.8), which can effectively assist the operator in detecting the subject, improve detection efficiency and user experience.
Advice: Please carefully read the product manual or purchase and use it under the guidance of medical personnel. Please refer to the manual for any contraindications or precautions.